Video: UK Regulation 31 Explained | Duration: 2028s | Summary: UK Regulation 31 Explained | Chapters: Webinar Introduction (8.8s), Introduction and Speakers (112.37s), Global Expansion and Accreditation (227.87s), Regulation 31 Purpose (414.365s), Regulation 31 Overview (535.41s), Approval Process Steps (647.52s), Regulation 31 Testing (842.72s), Leaching Testing Methods (1054.285s), GCMS Analysis (1225.095s), Project Timeline (1473.435s), Q&A Session (1692.125s), Q&A Session (1860.36s), Closing & Feedback (1980.775s)
Transcript for "UK Regulation 31 Explained":
Good morning everyone and welcome to NSF's webinar on UK regulation 31 explained. Before we begin a few brief housekeeping notes. Please note that this is a prerecorded webinar. Once the webinar presentation has concluded, miss Reema Thakur, senior project manager, global water division at NSF, will join us live to address your questions. If you have any questions during the presentation, please submit them via the chat or q and a panel. This seminar is being recorded and will be shared with registered attendees after the event. You can also download the webinar presentation from Doc Stack. Today's recorded session will be led by Samantha Duffy, senior manager of global water programs at NSF, who oversees NSF's EU and UK water certification skills and Gary Laban, senior specialist labs. So let's begin the session. Welcome, everyone, and thank you for joining us today for our NSF webinar, UK regulation 31 explained. My name is Julia Sotto. I will be your moderator for today's session, and I'm pleased to be joined by two NSF experts, Samantha Duffy, senior manager, global water programs, UKME schemes, and Gary Haven's senior specialist labs. Thank you again for joining us today. And with that, I will hand it over to Samantha. Thank you, Julia. If you move on to the next slide. Thank you. Morning, everybody. As Julie said, I'm Samantha Duffy. I am a senior manager. I'm the global program leader for all of our UK and European schemes, and we're really pleased to be with you today to talk about regulation 31. Good morning, everyone. My name is Gary Laban. As has already been said, I'm a senior specialist. I'll be the person who actually carries out the testing for reg 31 projects, and I will be leading, a number of them in the coming days, coming future. Thank you. Thanks, Gary. So I'd like to start by just introducing NSF for those who are not that familiar with us. So I often describe NSF as the most important organization you've never heard of. We benefit society by enabling safe and sustainable food, clean water, and life enhancing health technologies powered by expertise, innovation, and growth. In an era defined by a lack of trust in institutions, NSF is emerging as a purpose driven guardian of human and planet health, leaders in health, safety, and sustainability standards for us to say food, water, and health technologies. Can we move on, please, Julia? So in just over eight years, we've gone from a humble US centric nonprofit organization rooted in academia to a 3,000 plus person global organization where we've carried out testing and certification for more than 657 product. 657,000 products for over 40,000 companies. We're working across a 110 countries and partnering with governments and industry on food, water, health science, information security, and much, much more. Although NSF began in The United States, as you can see on this slide, we've grown into a truly global organization. Today, we operate across distinctive regions supported by more than 40 offices and laboratories worldwide. So no matter where you're located, you will have a local, facility. We're operating in a global market, and what that means is it comes with unique challenges, differences in regulations, working practices, time zones, and languages. That's why our team isn't centralized, and we're embedded within the regions we serve. And we call this a global approach. So we're delivering global expertise with local representation supported by multi multilingual team members who understand the market. We actively participate in more than a 170 technical and regulatory associations worldwide ranging from BSI and ANSI to the World Health Organization and leading academic institutions where we help shape standards, science, and policy. So it's clearly clear to say that we do have experience. In addition, our accreditation from bodies like UCAS, ANSI, and DACS all reinforce our testing certification and technical judgements meet those highest international benchmarks. So NSF, we work across a number of areas, food, water, and wellness. And we not only certify and test to those standards, we also develop standards. And we provide independent science based testing, assessment, inspection, and certification, which provides consumers and brands with that safe introduction of products to the market. So we're gonna move on to today's purpose, and that is to talk about regulation 31 and inform you that actually NSF are now a DWI designated lab for testing to rec 31. We're really proud of that. We know that there has been a big issue within the marketplace, and it has taken a while to gain this, designation. But we finally achieved this, and we're really pleased to be able to offer this as a service going forward. So let's start with why we need regulation 31. The answer is very simple. It's about the protection of water quality and the protection of the consumer of that water. That protection is required through the entire water cycle from source to tap and beyond, As we can see on this schematic, there are several materials and products that come into contact with drinking water at every stage. In relation to DWI regulation 31, which is the water supply water quality regulations, the message is that any product, material, chemical, or process used in the treatment, storage, transmission, or distribution of public drinking water must be approved and show no adverse, sorry, should show that it does not adversely affect water quality. So we can see here the key points of where regulation 31 approved products may be required. For example, source water extraction, so things like pumps, motors, intake, structure, and well linings. Water treatment works, treatment chemicals, filtration media, membranes, and equipment. Storage reservoirs and tanks, coatings, linings, seals, and tank components, distribution and network, the pipes, the valves, the pumps, the fittings, even the repair materials, customer premises, meters, filters, public components, plumbing components, and devices, and wastewater and recycled water interfaces. So in summary, protecting drinking water quality requires controlling every material that comes into contact with water throughout its journey from that source through the treatment works and distribution to the consumer, which is the fundamental purpose of the DWI regulation 31 approval. Now this slide's got rather a lot of information on here, and we will send the pack out to you. But in summary, regulation 31, it applies to materials and products in contact with public drinking water across England and Wales. Scotland and Northern Ireland have, single public supplies with their own risk assessments. It's reinforced by the drinking water inspectorate through product approval and testing. It requires submission of product formulation, test results, toxicology assessments, and manufacturing information. It covers application, testing, and approval fees. Products typically require testing every five years or whenever there's a significant change to the formulation or manufacturing, and there are no routine audits required as part of the approval process. So whilst we talk about water protection being required from source to tap, this little schematic on on the right is a good view of where reg 31 is applicable. It covers from the property boundary to the water source, so what I refer to as as upstream. Anything from the boundary into the property would be covered by regulation four for water supply water fittings regs nineteen ninety nine. Reg 31 does not include private water supplies, and it doesn't include appliances such as under sink filters and ice machines, etcetera. A practical rule of thumb, is that for The UK water utilities, if a material or coating or process contacts potable water on water company owned assets, it should be assessed the reg 31 applicability and any approval requirements. We actually look at products under regulation 31 in four product categories, and we attest according to their type and application. Most nonmetallic products require b s six nine two o and or leachate testing to assess potential impacts on the water quality while specialist products such as membranes, linings, repair materials, etcetera, could be subject to additional DWI protocol requirements. Small components may require some reduced testing. The overall aim is that we are to ensure that all products that are gonna come into contact with drinking water do not adversely affect the water quality. Now to gain regulation 31 approval, there are several steps that you must go through as you can see on this slide. Six steps in total. The first one being your product design and selection. So as the manufacturer, once you know what that is and that it's intended for use in public support apply, then it is about understanding that you may require regulation 31. You'd need to gather all of the information such as the formulation details. So anybody who's gone through certification for other types of products such as reg four will be familiar with that type of process, providing drawings, supporting information. Now you can use a consultant to do this. There are a number of consultants out there, but they must be approved by the DWI. And I'm sure if you look on their website, you'll be able to find a number of consultants out there that have been listed. The application then gets submitted to the DWI, not to NSF. The DWI will then review and assess the information provided, and that all sits with the DWI. Once they're happy with the information and their review, a test requirement letter will be issued to you as the client, as the customer. Once you have that TRL document, that is when you would approach NSF. At the moment, we are the only designated lab, and we need that information to be able to start the process. Once we have that information, then we can start to do our testing. Once the testing's been completed, we will provide you with the test report, and you then need to approach the DWI with your test report, and they will look to approve and list on their portal. So if you've worked with NSS before, and we do testing and certification, and we have our own listing portal, regulation 31 is slightly different. We do the testing only, and it is the DWI that will do the approval. And then they will enlist it on their approved product register. You'll be able to get access to that from the DWI website, but once you also receive this slide pack, you'll be able to follow the link. So I'm now gonna go over to, Gary, who's gonna do a bit of a deep dive into what regulation 31 testing is. Over to you, Gary. Thank you, Sam. Welcome to the, deep technical deep dive. Starting off here, we referred to Sam referred to the DWI, letter of testing that, that they will issue. And we've got it it looks fairly simple to begin with, but there's an awful lot of detail that is contained in this in this letter. If you start off the test sample requirements there, it's telling you there that it's actually a site this particular example is for a site applied material, and it's telling you to test to twelve eight seven three part two. And from that, we would definitely need the instructions for use. We need to follow those as a testing laboratory, as if it was actually being used in the real world, and that will include curing times, etcetera, if if, it is a resin of some description that needs to be cured. Moving on from there, the, the sample it gives you the sample I'm sorry. Don't go back to site. Sorry. I'm still working my way down this this particular particular list. There's an awful lot on this here. It tells you that, the leachate preparation, is twelve eight seven three part two, but there's no duplicate testing. So we're just looking at the one. However, if you then come to the test water, it says with and without chlorine present. That means we've gotta do two actually, through the process. The analytical requirements or determinants there, it tells you there is a GCMS general survey, total organic carbon, and then there's a number of specific determinants. And these are assays that are specific for those particular compounds. And, although we may detect them, through the general survey, the DWI is asking for a more accurate determination of the levels of these. And this requires a validated method to actually, carry out the the testing and finding out what the actual levels are of each of those. Note at the very bottom there, it says compounds a, b, and c. The letters that you will receive as, the applicant will not tell you what compounds a, b, and c are. However, the laboratory will apply to the DWI to find out what they cop the what their actual compounds are. It also says at the bottom of the letter that b s six nine two o full testing is required. So that that would be in addition to the reg 31 process as well. I would actually advise that you might want to do six nine two o in advance of reg 31 purely because it's cheaper to do six nine two o first. Sometimes we may do it in parallel, and we would do it in parallel for this particular site applied material. It has significant advantages of, getting the preparation of the the actual materials done at the same time using the same ingredients, and we can move forward from there. If we move on to the next slide. What is involved in the reg thirty two one project? For us as a testing laboratory, it means that the sample leaching or generation of water samples exposed to the actual test product, a pipe, or the site applied materials we used before. Yeah. So moving on, in terms of the reg 31 project, once you've got the samples to actually analyze, we will then put them through the, the GCMS screen, for the accurate quantitation of any specific determinants requesting, we'll also do that. The TOC, we will do. It's routine to do GCMS screen and TOC. The others are on top of those normal normal tests that we would perform. And then there's finally the writing of an analytical report to the customer. This report is gonna be quite extensive. Typically, it's gonna be around a 190 to a 150 pages worth of information. The DWI will then then make their judgment call on the the information that's presented should you choose to submit that to the client. Next slide next slide, please. So the leaching is covered by the BSEN twelve eight seven three, the influence of materials on on the water for human consumption. The next next part, please. Part one is, to do with the testing of glassy or porcelain vitreous enamel materials, and that would be cover the things like plastic pipes, etcetera. Part two is for the site applied materials, which we've covered previously. Part three is for ion exchange in absorbent resins. And finally, part four is the test method for the treatment for water treatment membranes themselves. Each one of those has a different leaching process, and it's defined in the in the actual standard itself. Next slide, please. This is an example of testing of a pipe in the, nice little picture that we've got there. You can see that there are two pipes. There's one with the laboratory purified water and with chlorinated water. And just in the background, you can just make out that there's two beakers that are corresponding blanks. So the same test waters in there, but there are no test products. That allows us to isolate that, compounds that we do detect are actually from the pipe and not something that we've inadvertently, picked up through the process of, leaching in the laboratory itself. Next slide, please. Total organic carbon analysis or TOC analysis. This is where we take the actual leachate waters, and we effectively burn it to produce carbon dioxide. It's a crude direct measurement of all the organic content within a leachate sample. It gives us a bit of an idea of what's going on. It also allows us to put that result against what we do find from the GCMS survey and allows us to see if there are any significant differences, and maybe something has got a right with the the testing itself or or, there's something we've missed along the way. It's a it's a bit of a check-in in effect. Next slide, please. The GCMS general survey sample preparation is one where we do a liquid liquid separation technique. That's an oil and water type, extraction. We we intimately mix the water sample with dichloromethane, and then we subsequently concentrate that dichloromethane extract, to a total of about 400 fold. So we take it from about 200 mil to half a mil and allows us to get a better, indication of what is actually in the samples themselves. It concentrates up the, things that may have been leached out of this out of the sample. Moving on to the actual equipment itself, this is a gas chromatography mass spectrometer, GCMS. It is separates the compounds that you've extracted through the, extraction process based on volatility of the compound and how much it actually likes or the affinity to the column that it passes through. And then finally, the detection is by the mass of each compound. That gives us a next slide, please. A simple chromatogram here. There's a number of compounds on there that we've actually physically added during the process of extraction and allows us to quantify what, how much, the the the pro how much each individual compound that we have found that has leached out. This is a nice simple one as I say. 10 of those compounds we've identified. This is not a simple one and would actually take quite a long time for us to go through, analyze what those compounds are, find out how much there are actually present also. If we move on to the next slide this is how we actually identify a compound it's from a fingerprint of each individual compound. So one of those peaks on the previous chromatogram will give rise to this mass spectrum that we can fit it against the library and identify what the compound is. Not all compounds are actually in the library, however, and some require an interpretation from someone like myself or preferably Richard who's a little bit more, experienced on this. You can you can interpret what the structure of the compound is by looking at the pattern of the peaks. You could determine whether it contains certain elements like chlorine. There there'll be a characteristic, pair of peaks for chlorine for a single chlorine atom, which will appear two mass units apart and in the ratio of two thirds and one third, and it's very characteristics. You might also see the loss of 35, the mass of, of chlorine from each of those peaks. So chlorine thirty five and thirty seven, you'll see another peak appearing at that, particular mass. That allows us that. There's other other things that we can look for as well in the mass spectrum to give us an idea of where where we are actually, looking at. Ultimately, it leads to a list of results. Thank you. Here we have a nice simple list of results. You can see there that most compounds have actually been identified, but there is the one at, 27.724 that states that we found two unknown compounds. We're not sure what they are. However, they we we can determine that they're actually chiral compounds. That's two compounds that are left handed and right handed. They're not actually the same, but they look the same. They're mirror images of each other. Interestingly, all life on Earth only uses the left handed form of amino acids. So that tells you something to how specific these things can be. They can behave differently biologically. It's a bit like a a lock and a key biologically, talking that you can, end up with different results for different compounds, although they look absolutely identical. There's other characteristics you can get from that as well. Specific determinants. As I said before, this is an assay for a particular compound. It is a much more focused assay. It's not the general survey. We will end up with much more accurate results as to the levels of these, And you may actually require a different sample extraction to the liquid liquid. We may, do you may do a different type of extraction. You may use, something called solid phase in order to do it. And it may also require a separate GCMS run with a different column, etcetera, in order to facilitate data analysis. And finally, how long to complete a project, which is probably a question that all of our customers actually ask, and it is so difficult to actually tell you definitely it's gonna take three days. It's not. It's gonna take several weeks to actually get to to the final answer for, a reg 31 project. It's very dependent on what, the project involves itself. The more specific determinants there are, the longer it will take. Each one of those assays has to be validated. If we don't already have an existing validated assay, we're gonna have to do some method development and then to actually, validate, the the assay itself. You really need to discuss, with the lab and the colleagues as to the interpretation of that DWI letter, and it can take several rounds of going backwards and forwards between ourselves and the DWI to establish exactly what they want and what they will accept. For a simple project requiring just the TOC, GCMS, general survey, and one specific determinant, it's about seventy to thirty one days from start to finish. That doesn't mean that it requires a 100% of lap time. It's just the time that it takes to generate the samples. Samples are leached over a period of generally sort of nine days. It may be long for some of the different different, membranes, etcetera. And then in interpretation, dirty samples, as you saw in that horrendous chromatogram, it will take a long time to actually interpret all of those peaks into a quantifiable compound and identified as well. And finally, next steps. Over to you, sir. Thanks, Gary. You made that sound so easy, Gary, but I know it's not. There's a lot of testing in detail there. Yeah. Thank you. So as we say, we we have our designation. The message is clear now that, you know, we have started to to work on reg 31, testing. We're able to do the b s six nine two o testing as well. So as Gary said earlier, if you require b s six nine two o, think about starting that now. Obviously, there has been a long, period of time for, approval of of the first lab. So we understand and, as I'm sure you will be, that there is a backlog of products there. So my suggestion is that if you do have any products that you want to have tested, then contact us now. You can send your information through to materials@nsf.org. It doesn't mean that we'll be necessarily be able to start your test next week, but we can put you in our planner, and we can give you an estimated start date. The sooner you let us know your requirements, the sooner you can join that queue. The longer you wait to do that, then the further down that queue you're gonna be. So please contact us. As I say, send it through via the email address there. You can also send your b s six nine two o requirements through to to that address as well. Once you have done that, you will be contacted by a dedicated project manager, and that project manager will work with you through the whole process, keeping you updated on how things are progressing. As Gary said, the time frame will depend on the product, and it will depend on the mix of products that we have at any one time. But what we are able to do is put you in that rotor, in that schedule, and we can give you an estimated time frame, and we can give you updates on how we are progressing towards that time frame. So on that note, that's as much as we had prepared on slides for today, and we'd now just like to open up to any questions that you have. We hope this session has provided greater clarity on the requirements and approval process for rec 31. We would like to take some questions now. We see there are already in the chat. Rima, would you like to answer? Yeah. Sure. Hi, everyone, and thanks for the questions. The interesting questions, like, let me first take this where the NSF lab is located in India. So we don't have lab in India, but we do have lab in, UK, which is Wales. So you need to send the samples to Wales. This is approved by DWI, which is drinking water, inspectorate. So you need to send it to there. And the next one, we can take it as if client already has b s 6920 testing. Do they need any additional testing for for did for this, like, Reg 30 1. B s 62920 covers the testings for, reg 31, but we need one additional testing, which is a leachate testing, which has been provided by DWI. So, yes, there is a specific testing required in addition for B s 6920, which needs to be complied. But, yes, 69 B s 6920 definitely helps you. And further, more details about it, we will share you, after the, this session. If you have already okay. This is why I have already addressed. Where can I find the current list of approved products and apply for approvals? Okay. Yes. There is a site of DWI government UK, which we can we will, just distribute to the to all the attendees, after this session. So you need you can go to that website, and there is a link for, all the approved materials there. And there's a link also to, apply for the applications as well. So we will share the further information about it. Yes. Okay. I I think we're conscious of time here. So before we close, a short feedback survey will pop up on your screen now. So we would greatly appreciate your feedback. Thank you, everyone, If we will definitely address your questions. have if you have any additional questions, please contact the team at @nsf.org. Thank you for joining us today and for your interest in NSF. We look forward to supporting you and your business through regulation 31 compliance journey. Have a great day, everyone. Thank you, Rima. Thank you.